{"id":2778,"date":"2007-07-21T15:59:20","date_gmt":"2007-07-21T20:59:20","guid":{"rendered":"https:\/\/schwingbioset.wpengine.com\/biosolid-land-application-requirements\/"},"modified":"2023-11-15T14:36:57","modified_gmt":"2023-11-15T20:36:57","slug":"biosolid-land-application-requirements","status":"publish","type":"post","link":"https:\/\/www.schwingbioset.com\/es\/biosolid-land-application-requirements\/","title":{"rendered":"Requisitos para la aplicaci\u00f3n de bios\u00f3lidos en terrenos"},"content":{"rendered":"<div class=\"hs-migrated-cms-post\">\n<p><img loading=\"lazy\" decoding=\"async\" id=\"img-1348512810669\" class=\"alignLeft\" style=\"float: left;\" src=\"\/\/cdn2.hubspot.net\/hub\/51084\/file-14384746-jpeg\/images\/biosolids1.jpeg\" alt=\"biosolids1\" width=\"250\" height=\"199\" border=\"0\" \/>EPA <span style=\"color: #339966;\"><strong><a style=\"color: #339966;\" href=\"https:\/\/www.epa.gov\/biosolids\" target=\"_blank\" rel=\"noopener nofollow\">Parte 503 <\/a><\/strong><\/span>La regla enumera cuatro opciones para cumplir con los l\u00edmites de contaminantes, pat\u00f3genos y vectores en los bios\u00f3lidos que se aplican a la tierra:<\/p>\n<ul>\n<li>Calidad excepcional (EQ)<\/li>\n<li>Concentraci\u00f3n de contaminantes (PC)<\/li>\n<li>Tasa de carga de contaminantes acumulados (CPLR)<\/li>\n<li>Tasa anual de carga de contaminantes (APLR)<\/li>\n<\/ul>\n<p>Each option is equally protective of the public health and the environment, so EQ, PC, CPLR, and APLR biosolids used in accordance with the Part 503 rule are all equally safe. For a detailed discussion on these four options, the best bet is to refer to the EPA, but the table below gives a brief primer on each.<\/p>\n<p><!--more--><\/p>\n<table style=\"width: 534px; height: 738px;\" border=\"1\" summary=\"biosolid land application requirements\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"120\"><strong>Opci\u00f3n*<\/strong><\/td>\n<td valign=\"top\" width=\"120\"><strong>L\u00edmites de contaminantes<\/strong><\/td>\n<td valign=\"top\" width=\"120\"><strong>Requisitos de pat\u00f3genos<\/strong><\/td>\n<td valign=\"top\" width=\"120\"><strong>Requisitos de reducci\u00f3n de atracci\u00f3n de vectores<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"120\"><strong>Bios\u00f3lidos de calidad excepcional (EQ)<\/strong><\/td>\n<td valign=\"top\" width=\"120\">Los bios\u00f3lidos a granel o en bolsas cumplen con los l\u00edmites de concentraci\u00f3n de contaminantes<\/td>\n<td valign=\"top\" width=\"120\">Cualquiera de los requisitos de Clase A enumerados <a title=\"aqu\u00ed\" href=\"https:\/\/www.schwingbioset.com\/es\/class-a-biosolids-vs-class-b-in-plain-english\/\" target=\"_blank\" rel=\"noopener\">aqu\u00ed<\/a><\/td>\n<td valign=\"top\" width=\"120\">Cualquiera de las opciones 1 a 8 enumeradas <a title=\"aqu\u00ed.\" href=\"https:\/\/www.schwingbioset.com\/es\/whats-your-vector\/\" target=\"_blank\" rel=\"noopener\">aqu\u00ed.<\/a><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" valign=\"top\" width=\"120\"><strong>Bios\u00f3lidos de concentraci\u00f3n de contaminantes (PC)<\/strong><\/td>\n<td rowspan=\"2\" valign=\"top\" width=\"120\">Los bios\u00f3lidos a granel cumplen con los l\u00edmites de concentraci\u00f3n de contaminantes<\/td>\n<td valign=\"top\" width=\"120\">Cualquiera de los requisitos de Clase B enumerados <a title=\"aqu\u00ed\" href=\"https:\/\/www.schwingbioset.com\/es\/class-a-biosolids-vs-class-b-in-plain-english\/\" target=\"_blank\" rel=\"noopener\">aqu\u00ed<\/a><\/td>\n<td valign=\"top\" width=\"120\">Cualquiera de las diez opciones enumeradas <a title=\"aqu\u00ed.\" href=\"https:\/\/www.schwingbioset.com\/es\/whats-your-vector\/\" target=\"_blank\" rel=\"noopener\">aqu\u00ed.<\/a><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"120\">Cualquiera de los requisitos de Clase A enumerados <a title=\"&lt;a title=\" href=\"https:\/\/www.schwingbioset.com\/es\/class-a-biosolids-vs-class-b-in-plain-english\/\" target=\"_blank\" rel=\"noopener\">aqu\u00ed<\/a><\/td>\n<td valign=\"top\" width=\"120\">Opci\u00f3n 9 o 10 enumerada<a title=\"aqu\u00ed.\" href=\"https:\/\/www.schwingbioset.com\/es\/whats-your-vector\/\" target=\"_blank\" rel=\"noopener\"> aqu\u00ed.<\/a><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"120\"><strong>Tasa de carga de contaminantes acumulados (CPLR) Bios\u00f3lidos<\/strong><\/td>\n<td valign=\"top\" width=\"120\">Bios\u00f3lidos a granel aplicados sujetos a los l\u00edmites de tasa de carga de contaminantes acumulados enumerados <a href=\"https:\/\/www.schwingbioset.com\/es\/the-anatomy-of-class-a-bisosolids\/\" target=\"_blank\" rel=\"noopener\">aqu\u00ed<\/a><\/td>\n<td valign=\"top\" width=\"120\">Cualquiera de los requisitos de Clase A o Clase B enumerados <a title=\"aqu\u00ed\" href=\"https:\/\/www.schwingbioset.com\/es\/class-a-biosolids-vs-class-b-in-plain-english\/\" target=\"_blank\" rel=\"noopener\">aqu\u00ed<\/a><\/td>\n<td valign=\"top\" width=\"120\">Cualquiera de las diez opciones enumeradas <a title=\"aqu\u00ed.\" href=\"https:\/\/www.schwingbioset.com\/es\/whats-your-vector\/\" target=\"_blank\" rel=\"noopener\">aqu\u00ed.<\/a><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"120\"><strong>Tasa anual de carga de contaminantes (APLR) Bios\u00f3lidos<\/strong><\/td>\n<td valign=\"top\" width=\"120\">Los bios\u00f3lidos envasados se aplican sujetos a los l\u00edmites de la tasa de carga de contaminantes anuales<\/td>\n<td valign=\"top\" width=\"120\">Cualquiera de los requisitos de Clase A enumerados <a href=\"https:\/\/www.schwingbioset.com\/es\/class-a-biosolids-vs-class-b-in-plain-english\/\" target=\"_blank\" rel=\"noopener\">aqu\u00ed<\/a><\/td>\n<td valign=\"top\" width=\"120\">Cualquiera de las opciones 1 a 8 enumeradas<a title=\"aqu\u00ed.\" href=\"https:\/\/www.schwingbioset.com\/es\/whats-your-vector\/\" target=\"_blank\" rel=\"noopener\"> aqu\u00ed.<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* Cada una de estas opciones requiere que los bios\u00f3lidos cumplan con las concentraciones m\u00e1ximas de contaminantes, los requisitos de monitoreo y los requisitos de mantenimiento de registros y presentaci\u00f3n de informes. Ver el <a href=\"https:\/\/www.epa.gov\/biosolids\/plain-english-guide-epa-part-503-biosolids-rule\" target=\"_blank\" rel=\"noopener nofollow\">Regla de la parte 503 de la EPA, cap\u00edtulo 2<\/a> para m\u00e1s informaci\u00f3n.<\/p>\n<p>Schwing Bioset\u2019s advanced processing technology can help you understand and meet these requirements.<\/p>\n<p><a href=\"https:\/\/www.schwingbioset.com\/es\/contact\/\" target=\"_blank\" rel=\"noopener\"><strong><span style=\"color: #339966;\">Cont\u00e1ctenos<\/span><\/strong><\/a><strong>\u00a0<\/strong>today to learn how Schwing Bioset can help your operation, or<strong>\u00a0<\/strong><span style=\"color: #339966;\"><a style=\"color: #339966;\" href=\"https:\/\/www.schwingbioset.com\/es\/\" target=\"_blank\" rel=\"noopener\"><strong>Visite nuestro sitio web<\/strong><\/a><\/span><strong>\u00a0<\/strong>to read more about our products and solutions.<\/p>\n<p>&nbsp;<\/p>\n<a href=\"https:\/\/www.schwingbioset.com\/es\/downloads\/\" class=\"small-button smallsilver\" target=\"_blank\">Descargue nuestros folletos e informes de aplicaciones<\/a>\n<a href=\"https:\/\/www.schwingbioset.com\/es\/news-subscribe\/\" class=\"small-button smallsilver\" target=\"_blank\">Subscribe to Start Receiving Schwing Bioset eNews<\/a>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>EPA Part 503 rule lists four options for meeting pollutant, pathogen, and vector limits in biosolids that are applied to land: Exceptional Quality (EQ) Pollutant Concentration (PC) Cumulative Pollutant Loading rate (CPLR) Annual Pollutant Loading Rate (APLR) Each option is equally protective of the public health and the environment, so EQ, PC, CPLR, and APLR [&hellip;]<\/p>","protected":false},"author":2,"featured_media":3667,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","content-type":"","footnotes":""},"categories":[277,16],"tags":[173,188],"class_list":["post-2778","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bioset-class-a","category-news","tag-biosolids","tag-wastewater-treatment"],"_links":{"self":[{"href":"https:\/\/www.schwingbioset.com\/es\/wp-json\/wp\/v2\/posts\/2778","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.schwingbioset.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.schwingbioset.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.schwingbioset.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.schwingbioset.com\/es\/wp-json\/wp\/v2\/comments?post=2778"}],"version-history":[{"count":0,"href":"https:\/\/www.schwingbioset.com\/es\/wp-json\/wp\/v2\/posts\/2778\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.schwingbioset.com\/es\/wp-json\/wp\/v2\/media?parent=2778"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.schwingbioset.com\/es\/wp-json\/wp\/v2\/categories?post=2778"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.schwingbioset.com\/es\/wp-json\/wp\/v2\/tags?post=2778"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}